Purpose

• measuring of leakages through the gate element of control valve during testing with water.

Parameter

BR

The range of measurement of waterflow rate:

- flow meter, l/min.

0,0072...56,0

Class of sensor accuracy II-VI (50% scale),%

1

Operation conditions:

- ambient air temperature, °C (ºF);

from +5 (+41) to +40 (+104)

- relative humidity (at + 25 °C)%.

30...80

Overall dimensions (LxWxH), mm (″)

705х665х1335 (28х26х53)

Weight, kg

30


Advantages

  • High precision and visibility when testing for gate tightness with air. 
  • A large range of measured leakage allows testing of control valves with tightness class II-VI as per (ANSI / FCI 70-2). 
  • Unit allows to connect additional flow sensors to register the leakages by using computer registration system CRS.* 
  • Mobile design of the unit allows to move it between the different benches, depending on the need for testing of control valves. 
  • Built-in filter eliminates the need to clean the flowmeters in contact with foreign particles from the tested valves.


* Upon customer request.

Video