Multi-station test bench for shut off valves DN 10...200 mm (⅜...8″)

Purpose

• pneumatic and hydraulic testing of shut off valve; 
• gate tightness tests; 
• environmental leakage tests (including gland seals); 
• operation test.

Tested items

• gate valves; 
• globe valves; 
• ball valves.

Tested unit connection type

• flanged (according ASME B 16.5, GOST 12815 etc.); 
• welded ends (according ASME B 16.25, GOST 16037 , etc.).

Asset 122.svg

Parameter

S-35-200/18-3

Maximum clamping force, t (station №1/stations №2,3)

18/2,2

Min./max. length of the tested valve, mm (″)

130/400 (5/15,94)

Min./max. diameter of the clamped flange, mm (″)

95/335 (4/13)

Overall dimensions (LхWхH), mm (″)

2582х1478х2206 (101х58х87)

Weight, kg

1650


Advantages

  • The test bench consists of a station for hydraulic tests and station for pneumatic tests. 
  • Quantity of clamping units could be changed upon customer request.* 
  • The test bench can be produced with vertical or horizontal test stations, and with the combination of two of them.* 
  • The test bench includes a control panel. 
  • Units and details of the test bench are protected from corrosion.
  • Allows fast and accurate testing of a large quantity of serial products. 
  • The test bench is equipped with a control system that provides:
  • light indication on the presence of pressure in the valve; 
  • the system that prevents the tested valve unclamping in the presence of pressure therein; 
  • setting the time of tests; 
  • automatic detection of tested valve’s gate leakage with a light signal.

* Upon customer request.

Video

Optional