Purpose
- measuring of leakages through the gate element of control valve during testing with air.
Parameter |
MIP-W |
Operation medium |
water according to GOST R 51232* |
Accuracy class, % |
±5,0 |
Range of airflow rate measurement |
0,0072...56 l/min |
Operation conditions: |
|
- ambient air temperature, °C (ºF); |
from +5 (+41) to +40 (+104) |
- relative humidity (at + 25 °C)%. |
30...80 |
Overall dimensions (LxWxH), mm (″) |
705х665х1335 (28х26х53) |
Weight, kg |
30 |
* Upon customer request. |
- High precision and visibility when testing for gate tightness with air.
- A large range of measured leakage allows testing of control valves with tightness class II-VI as per (ANSI / FCI 70-2).
- Unit allows to connect additional flow sensors to register the leakages by using computer registration system CRS.*
- Mobile design of the unit allows to move it between the different benches, depending on the need for testing of control valves.
- Built-in filter eliminates the need to clean the flowmeters in contact with foreign particles from the tested valves.
* Upon customer request.