Test bench for shut off valves DN 50...500 mm (2...20″)

Purpose

  • shell test acc. to API 598, API 6D, ISO 5208 etc.;
  • seat leakage test (cavities A to B, B to A) acc. to API 598, API 6D, ISO 5208 etc.;
  • backseat test acc. to API 598, API 6D, ISO 5208 etc.;
  • DBB/DIB test acc. to API 598, API 6D;
  • control valve seat leakage test, acc. to ANSI FCI 70.2, IEC 60534-4, EN 1349 etc.

Tested valves

  • gate valves; 
  • ball valves; 
  • butterfly valves; 
  • check valves; 
  • plug valves;
  • control valves.

Connection type

  • flanged (according ASME B 16.5, ASME B 16.47, GOST 12815 etc.); 
  • welded ends (according ASME B 16.25, GOST 16037, etc.);* 
  • set of sealing adapters available.* 


* Upon customer request.

Asset 99.svg

  • Clamping of tested valve is provided by hydraulic cylinder. Optionally test bench can be equipped with proportional clamping control system, which excludes axial compression applied to the valve body during clamping by hydraulic cylinder, during high pressure testing.* 
  • Clamping unit can be provided with radial sealing type or self-sealing adapters.* 
  • The two-sided gate sealing during tests does not require the tested valve rearrangement, which significantly reduces the test time. 
  • The bench is equipped with a special system for air removal from the tested valve, which improves safety, productivity, reliability of the obtained data, and obviates the need for additional air drain.* 
  • The bench is equipped with the water-collection tray with stainless steel tank.* 
  • The test preparation time is significantly reduced by using the high-pressure quick-connect hoses. 
  • The bench is quickly adjusted to face-to-face dimensions of valve by using the hydraulically or electrically driven cross-head. 
  • The patented design of the self-sealing adapters exclude axial compression during the tests, which ensures the test reliability, protects the valves against deformation, and extends the valve life.* 
  • All water-wetted parts are corrosion-proof. 
  • The bench can be equipped with replaceable sealing adapters.* 
  • Increased-diameter hoses reduce the time of the valve filling with the test medium. 
  • Test bench can be equipped with valve lifting platforms for valve positioning and support during testing.*
* Upon customer request.

Video

Optional